Artigo em Inglês | MEDLINE | ID: mdl-35100111

RESUMO

Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound velocity of the aberrator (i.e., the skull) is estimated using the bidirectional headwave technique. The medium is described with four layers (i.e., lens, water, skull, and water), and a fast marching method calculates the travel times between individual array elements and image pixels. Finally, a delay-and-sum algorithm is used for image reconstruction with coherent compounding. The point spread function (PSF) in a wire phantom image and reconstructed with the conventional technique (using a constant sound speed throughout the medium), and the proposed method was quantified with numerical synthetic data and experiments with a bone-mimicking plate and a human skull, compared with the PSF achieved in a ground truth image of the medium without the aberrator (i.e., the bone plate or skull). A phased-array transducer (P4-1, ATL/Philips, 2.5 MHz, 96 elements, pitch = 0.295 mm) was used for the experiments. The results with the synthetic signals, the bone-mimicking plate, and the skull indicated that the proposed method reconstructs the scatterers with an average lateral/axial localization error of 0.06/0.14 mm, 0.11/0.13 mm, and 1.0/0.32 mm, respectively. With the human skull, an average contrast ratio (CR) and full-width-half-maximum (FWHM) of 37.1 dB and 1.75 mm were obtained with the proposed approach, respectively. This corresponds to an improvement of CR and FWHM by 7.1 dB and 36% compared with the conventional method, respectively. These numbers were 12.7 dB and 41% with the bone-mimicking plate.


Assuntos
Processamento de Imagem Assistida por Computador , Crânio , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Crânio/diagnóstico por imagem , Ultrassonografia
2.
Ultrasound Med Biol ; 48(1): 149-156, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34629191

RESUMO

The potential of proton therapy to improve the conformity of the delivered dose to the tumor volume is currently limited by range uncertainties. Injectable superheated nanodroplets have recently been proposed for ultrasound-based in vivo range verification, as these vaporize into echogenic microbubbles on proton irradiation. In previous studies, offline ultrasound images of phantoms with dispersed nanodroplets were acquired after irradiation, relating the induced vaporization profiles to the proton range. However, the aforementioned method did not enable the counting of individual vaporization events, and offline imaging cannot provide real-time feedback. In this study, we overcame these limitations using high-frame-rate ultrasound imaging with a linear array during proton irradiation of phantoms with dispersed perfluorobutane nanodroplets at 37°C and 50°C. Differential image analysis of subsequent frames allowed us to count individual vaporization events and to localize them with a resolution beyond the ultrasound diffraction limit, enabling spatial and temporal quantification of the interaction between ionizing radiation and nanodroplets. Vaporization maps were found to accurately correlate with the stopping distribution of protons (at 50°C) or secondary particles (at both temperatures). Furthermore, a linear relationship between the vaporization count and the number of incoming protons was observed. These results indicate the potential of real-time high-frame-rate contrast-enhanced ultrasound imaging for proton range verification and dosimetry.


Assuntos
Microbolhas , Prótons , Imagens de Fantasmas , Ultrassonografia , Volatilização
3.
Artigo em Inglês | MEDLINE | ID: mdl-33739922

RESUMO

In the above article [1], the authors regret that there was a mistake in calculating the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was utilized and the conversion mistake only came when converting to mol% in order to define the ratio between the coating formulation components. The correct molecular weight of PEG-40 stearate is 2046.54 g/mol [2], [3], not 328.53 g/mol. On page 556, Table I should read as shown here.

4.
Artigo em Inglês | MEDLINE | ID: mdl-33460371

RESUMO

The utility of ultrasound imaging and therapy with microbubbles may be greatly enhanced by determining their impulse-response dynamics as a function of size and composition. Prior methods for microbubble characterization utilizing high-speed cameras, acoustic transducers and laser-based techniques typically scan a limited frequency range. Here, we report on the use of a novel photoacoustic technique to measure the impulse response of single microbubbles. Individual microbubbles are driven with a broadband photoacoustic wave generated by a nanosecond-pulse laser illuminating an optical absorber. The resulting microbubble oscillations were detected by following transmission of a second laser as it passes twice through the microbubble. The system could even resolve oscillations resulting from a single-shot. As a proof-of-concept study, the size-dependent, linear impulse response of lipid-coated microbubbles was characterized using this technique. This unique method of microbubble characterization with exceptional spatiotemporal resolution opens new avenues for capturing and analyzing microbubble system dynamics.


Assuntos
Meios de Contraste , Microbolhas , Acústica , Lipídeos , Ultrassonografia
5.
Artigo em Inglês | MEDLINE | ID: mdl-32746204

RESUMO

Phase aberration in transcranial ultrasound imaging (TUI) caused by the human skull leads to an inaccurate image reconstruction. In this article, we present a novel method for estimating the speed of sound and an adaptive beamforming technique for phase aberration correction in a flat polyvinylchloride (PVC) slab as a model for the human skull. First, the speed of sound of the PVC slab is found by extracting the overlapping quasi-longitudinal wave velocities of symmetrical Lamb waves in the frequency-wavenumber domain. Then, the thickness of the plate is determined by the echoes from its front and back side. Next, an adaptive beamforming method is developed, utilizing the measured sound speed map of the imaging medium. Finally, to minimize reverberation artifacts caused by strong scatterers (i.e., needles), a dual probe setup is proposed. In this setup, we image the medium from two opposite directions, and the final image can be the minimum intensity projection of the inherently co-registered images of the opposed probes. Our results confirm that the Lamb wave method estimates the longitudinal speed of the slab with an error of 3.5% and is independent of its shear wave speed. Benefiting from the acquired sound speed map, our adaptive beamformer reduces (in real time) a mislocation error of 3.1, caused by an 8 mm slab, to 0.1 mm. Finally, the dual probe configuration shows 7 dB improvement in removing reverberation artifacts of the needle, at the cost of only 2.4-dB contrast loss. The proposed image formation method can be used, e.g., to monitor deep brain stimulation procedures and localization of the electrode(s) deep inside the brain from two temporal bones on the sides of the human skull.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Humanos , Imagens de Fantasmas , Som , Ultrassonografia
6.
Artigo em Inglês | MEDLINE | ID: mdl-33338016

RESUMO

In our paper titled "Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging" [1], we mentioned that the superposition of the different symmetric (S) modes in the frequency-wavenumber (f-k) domain results in a high intensity region where its slope corresponds to the longitudinal wave speed in the slab. However, we have recently understood that this high intensity region belongs to the propagation of a wave called lateral wave or head wave [2-5]. It is generated if the longitudinal sound speed of the aberrator (i.e. the PVC slab) is larger than that of water and if the incident wavefront is curved. When the incidence angle at the interface between water and PVC is near the critical angle, the refracted wave in PVC re-radiates a small part of its energy into the fluid (i.e. the head wave). As discussed in [4], if the thickness of the waveguide is larger than the wavelength, the first arriving signal is the head wave. This is also the case in our study [1] where the ultrasound wavelength of a compressional wave in PVC was close to 1 mm, and a PVC slab with a thickness of 8 mm was used.

7.
Appl Phys Lett ; 116(12): 123703, 2020 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-32231399

RESUMO

The interaction between an acoustically driven microbubble and a surface is of interest for a variety of applications, such as ultrasound imaging and therapy. Prior investigations have mainly focused on acoustic effects of a rigid boundary, where it was generally observed that the wall increases inertia and reduces the microbubble resonance frequency. Here we investigate the response of a lipid-coated microbubble adherent to a rigid wall. Firm adhesion between the microbubble and a glass surface was achieved through either specific (biotin/avidin) or nonspecific (lipid/glass) interactions. Total internal reflection fluorescence microscopy was used to verify conditions leading to either adhesion or non-adhesion of the bubble to a glass or rigid polymer surface. Individual microbubbles were driven acoustically to sub-nanometer-scale radial oscillations using a photoacoustic technique. Remarkably, adherent microbubbles were shown to have a higher resonance frequency than non-adherent microbubbles resting against the wall. Analysis of the resonance curves indicates that adhesion stiffens the bubble by an apparent increase in the shell elasticity term and decrease in the shell viscosity. Based on these results, we conclude that surface adhesion is dominant over acoustic effects for low-amplitude microbubble oscillations.

8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2111-2114, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946317

RESUMO

Effective treatment of movement disorders requires thorough understanding of human limb control. Joint dynamics can be assessed using robotic manipulators and system identification. Due to tendon compliance, joint angle and muscle length are not proportional. This study uses plane-wave ultrasound imaging to investigate the dynamic relation between ankle joint angle and muscle fiber stretch. The first goal is to determine the feasibility of using ultrasound imaging with system identification; the second goal is to assess the relation between ankle angle, muscle stretch, and reflex size. Soleus and gastrocnemius muscle stretches were assessed with ultrasound imaging and image tracking. For small (1° SD) continuous motions, muscle stretch was proportional to ankle angle during a relax task, but images were too noisy to make that assessment during an active position task. For transient perturbations with high velocity (> 90°/s) the muscle length showed oscillations that were not present in the ankle angle, demonstrating a non-proportional relationship and muscle-tendon interaction. The gastrocnemius velocity predicted the size of the short-latency reflex better than the ankle angle velocity. Concluding, plane-wave ultrasound muscle imaging is feasible for system identification experiments and shows that muscle length and ankle angle are proportional during a relax task with small continuous perturbations.


Assuntos
Articulação do Tornozelo/fisiologia , Músculo Esquelético/diagnóstico por imagem , Ultrassonografia , Tornozelo/fisiologia , Humanos , Músculo Esquelético/fisiologia , Tendões/fisiologia
9.
Ultrasound Med Biol ; 44(10): 2143-2154, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30072206

RESUMO

This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a partitioned transmit/receive array architecture wherein the 8 × 8 transmitter elements, located at the centre of the array, are directly wired out and the remaining receive elements are grouped into 96 sub-arrays of 3 × 3 elements. The echoes received by these sub-groups are locally processed by micro-beamformer circuits in the ASIC that allow pre-steering up to ±37°. The PZT-on-CMOS matrix transducer has been characterized acoustically and has a centre frequency of 5.8 MHz, -6 dB bandwidth of 67%, a transmit efficiency of 6 kPa/V at 30 mm, and a receive dynamic range of 85 dB with minimum and maximum detectable pressures of 5 Pa and 84 kPa respectively. The properties are very suitable for a miniature pediatric real-time 3D TEE probe.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Transdutores , Acústica , Criança , Ecocardiografia Tridimensional/instrumentação , Desenho de Equipamento , Humanos , Pediatria/métodos
10.
Ultrasound Med Biol ; 44(9): 2025-2042, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30037476

RESUMO

We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The elements of the larger square receive aperture are grouped in 4 × 4-element sub-arrays by micro-beamforming in an application-specific integrated circuit. We propose a beamforming sequence with 85 transmit-receive events that exhibits good performance for a volume sector of 60°â€¯× 60°. The beamforming is validated using Field II simulations, phantom measurements and in vivo imaging. The proposed parallel beamforming achieves volume rates up to 59 Hz and produces good-quality images by angle-weighted combination of overlapping sub-volumes. Point spread function, contrast ratio and contrast-to-noise ratio in the phantom experiment closely match those of the simulation. In vivo 3-D imaging at 22-Hz volume rate in a healthy adult pig clearly visualized the cardiac structures, including valve motion.


Assuntos
Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Animais , Modelos Animais , Imagens de Fantasmas , Reprodutibilidade dos Testes , Suínos , Transdutores
11.
Artigo em Inglês | MEDLINE | ID: mdl-30047876

RESUMO

Intravascular ultrasound (IVUS) is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking IVUS (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2-D array transducers, which present major challenges in reducing cable count and device integration. In this work, we present an 80-element lead zirconium titanate matrix ultrasound transducer for FL-IVUS imaging with a front-end application-specific integrated circuit (ASIC) requiring only four cables. After investigating optimal transducer designs, we fabricated the matrix transducer consisting of 16 transmit (TX) and 64 receive (RX) elements arranged on top of an ASIC having an outer diameter of 1.5 mm and a central hole of 0.5 mm for a guidewire. We modeled the transducer using finite-element analysis and compared the simulation results to the values obtained through acoustic measurements. The TX elements showed uniform behavior with a center frequency of 14 MHz, a -3-dB bandwidth of 44%, and a transmit sensitivity of 0.4 kPa/V at 6 mm. The RX elements showed center frequency and bandwidth similar to the TX elements, with an estimated receive sensitivity of /Pa. We successfully acquired a 3-D FL image of three spherical reflectors in water using delay-and-sum beamforming and the coherence factor method. Full synthetic-aperture acquisition can be achieved with frame rates on the order of 100 Hz. The acoustic characterization and the initial imaging results show the potential of the proposed transducer to achieve 3-D FL-IVUS imaging.

12.
Artigo em Inglês | MEDLINE | ID: mdl-28113312

RESUMO

Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of C4F10 and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter ~1 [Formula: see text]) than sonication (number weighted mean diameter ~2 [Formula: see text]). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available Target-Ready MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney ( n = 7 ), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.


Assuntos
Meios de Contraste/química , Microbolhas , Ultrassonografia/métodos , Animais , Feminino , Suínos
13.
Ultrasound Med Biol ; 42(9): 2283-93, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27302657

RESUMO

Angiogenesis is a critical feature of plaque development in atherosclerosis and might play a key role in both the initiation and later rupture of plaques. The precursory molecular or cellular pro-angiogenic events that initiate plaque growth and that ultimately contribute to plaque instability, however, cannot be detected directly with any current diagnostic modality. This study was designed to investigate the feasibility of ultrasound molecular imaging of endothelial αvß3 expression in vitro and in vivo using αvß3-targeted ultrasound contrast agents (UCAs). In the in vitro study, αvß3 expression was confirmed by immunofluorescence in a murine endothelial cell line and detected using the targeted UCA and ultrasound imaging at 18-MHz transmit frequency. In the in vivo study, expression of endothelial αvß3 integrin in murine carotid artery vessels and microvessels of the salivary gland was quantified using targeted UCA and high-frequency ultrasound in seven animals. Our results indicated that endothelial αvß3 expression was significantly higher in the carotid arterial wall containing atherosclerotic lesions than in arterial segments without any lesions. We also found that the salivary gland can be used as an internal positive control for successful binding of targeted UCA to αvß3 integrin. In conclusion, αvß3-targeted UCA allows non-invasive assessment of the expression levels of αvß3 on the vascular endothelium and may provide potential insights into early atherosclerotic plaque detection and treatment monitoring.


Assuntos
Meios de Contraste , Endotélio Vascular/diagnóstico por imagem , Aumento da Imagem/métodos , Integrina alfaVbeta3/metabolismo , Microbolhas , Ultrassonografia/métodos , Animais , Técnicas In Vitro , Integrina alfaVbeta3/genética , Masculino , Camundongos , Camundongos Knockout , Modelos Animais
14.
Ultrasound Med Biol ; 42(8): 2017-25, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27181689

RESUMO

The identification of unstable atherosclerotic plaques in the coronary arteries is emerging as an important tool for guiding percutaneous coronary interventions and may enable preventive treatment of such plaques in the future. Assessment of plaque stability requires imaging of both structure and composition. Spectroscopic photoacoustic (sPA) imaging can visualize atherosclerotic plaque composition on the basis of the optical absorption contrast. It is an established fact that the frequency content of the photoacoustic (PA) signal is correlated with structural tissue properties. As PA signals can be weak, it is important to match the transducer bandwidth to the signal frequency content for in vivo imaging. In this ex vivo study on human coronary arteries, we combined sPA imaging and analysis of frequency content of the PA signals. Using a broadband transducer (-3-dB one-way bandwidth of 10-35 MHz) and a 1-mm needle hydrophone (calibrated for 1-20 MHz), we covered a large frequency range of 1-35 MHz for receiving the PA signals. Spectroscopic PA imaging was performed at wavelengths ranging from 1125 to 1275 nm with a step of 2 nm, allowing discrimination between plaque lipids and adventitial tissue. Under sPA imaging guidance, the frequency content of the PA signals from the plaque lipids was quantified. Our data indicate that more than 80% of the PA energy of the coronary plaque lipids lies in the frequency band below 8 MHz. This frequency information can guide the choice of the transducer element used for PA catheter fabrication.


Assuntos
Aterosclerose/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Técnicas Fotoacústicas/métodos , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia/métodos , Cadáver , Simulação por Computador , Humanos , Imagens de Fantasmas
15.
Ultrasound Med Biol ; 42(5): 1239-43, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26856788

RESUMO

Intravascular photoacoustic (IVPA) imaging can visualize the coronary atherosclerotic plaque composition on the basis of the optical absorption contrast. Most of the photoacoustic (PA) energy of human coronary plaque lipids was found to lie in the frequency band between 2 and 15 MHz requiring a very broadband transducer, especially if a combination with intravascular ultrasound is desired. We have developed a broadband polyvinylidene difluoride (PVDF) transducer (0.6 × 0.6 mm, 52 µm thick) with integrated electronics to match the low capacitance of such a small polyvinylidene difluoride element (<5 pF/mm(2)) with the high capacitive load of the long cable (∼100 pF/m). The new readout circuit provides an output voltage with a sensitivity of about 3.8 µV/Pa at 2.25 MHz. Its response is flat within 10 dB in the range 2 to 15 MHz. The root mean square (rms) output noise level is 259 µV over the entire bandwidth (1-20 MHz), resulting in a minimum detectable pressure of 30 Pa at 2.25 MHz.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Sistemas Microeletromecânicos/instrumentação , Polivinil/química , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Amplificadores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Polivinil/efeitos da radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Ondas Ultrassônicas , Interface Usuário-Computador
16.
Artigo em Inglês | MEDLINE | ID: mdl-26067053

RESUMO

Molecular markers associated with diseases can be visualized and quantified noninvasively with targeted ultrasound contrast agent (t-UCA) consisting of microbubbles (MBs) that can bind to specific molecular targets. Techniques used for quantifying t-UCA assume that all unbound MBs are taken out of the blood pool few minutes after injection and only MBs bound to the molecular markers remain. However, differences in physiology, diseases, and experimental conditions can increase the longevity of unbound MBs. In such conditions, unbound MBs will falsely be quantified as bound MBs. We have developed a novel technique to distinguish and classify bound from unbound MBs. In the post-processing steps, first, tissue motion was compensated using block-matching (BM) techniques. To preserve only stationary contrast signals, a minimum intensity projection (MinIP) or 20th-percentile intensity projection (PerIP) was applied. The after-flash MinIP or PerIP was subtracted from the before-flash MinIP or PerIP. In this way, tissue artifacts in contrast images were suppressed. In the next step, bound MB candidates were detected. Finally, detected objects were tracked to classify the candidates as unbound or bound MBs based on their displacement. This technique was validated in vitro, followed by two in vivo experiments in mice. Tumors (n = 2) and salivary glands of hypercholesterolemic mice (n = 8) were imaged using a commercially available scanner. Boluses of 100 µL of a commercially available t-UCA targeted to angiogenesis markers and untargeted control UCA were injected separately. Our results show considerable reduction in misclassification of unbound MBs as bound ones. Using our method, the ratio of bound MBs in salivary gland for images with targeted UCA versus control UCA was improved by up to two times compared with unprocessed images.


Assuntos
Meios de Contraste/química , Processamento de Imagem Assistida por Computador/métodos , Microbolhas , Imagem Molecular/métodos , Ultrassonografia/métodos , Algoritmos , Animais , Linhagem Celular Tumoral , Humanos , Masculino , Camundongos , Camundongos Knockout , Camundongos Nus , Imagens de Fantasmas
17.
Artigo em Inglês | MEDLINE | ID: mdl-25768814

RESUMO

This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.


Assuntos
Meios de Contraste/química , Microbolhas , Álcool de Polivinil/química , Acústica , Teste de Materiais , Óptica e Fotônica
18.
Int J Hyperthermia ; 31(2): 90-106, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25707815

RESUMO

Ultrasound contrast agents (UCAs) are used routinely in the clinic to enhance contrast in ultrasonography. More recently, UCAs have been functionalised by conjugating ligands to their surface to target specific biomarkers of a disease or a disease process. These targeted UCAs (tUCAs) are used for a wide range of pre-clinical applications including diagnosis, monitoring of drug treatment, and therapy. In this review, recent achievements with tUCAs in the field of molecular imaging, evaluation of therapy, drug delivery, and therapeutic applications are discussed. We present the different coating materials and aspects that have to be considered when manufacturing tUCAs. Next to tUCA design and the choice of ligands for specific biomarkers, additional techniques are discussed that are applied to improve binding of the tUCAs to their target and to quantify the strength of this bond. As imaging techniques rely on the specific behaviour of tUCAs in an ultrasound field, it is crucial to understand the characteristics of both free and adhered tUCAs. To image and quantify the adhered tUCAs, the state-of-the-art techniques used for ultrasound molecular imaging and quantification are presented. This review concludes with the potential of tUCAs for drug delivery and therapeutic applications.


Assuntos
Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Imagem Molecular/métodos , Terapia por Ultrassom , Ultrassonografia , Sistemas de Liberação de Medicamentos , Humanos , Microbolhas
19.
Ultrasound Med Biol ; 41(2): 486-97, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25592458

RESUMO

There is increasing use of ultrasound contrast agent in high-frequency ultrasound imaging. However, conventional contrast detection methods perform poorly at high frequencies. We performed systematic in vitro comparisons of subharmonic, non-linear fundamental and ultraharmonic imaging for different depths and ultrasound contrast agent concentrations (Vevo 2100 system with MS250 probe and MicroMarker ultrasound contrast agent, VisualSonics, Toronto, ON, Canada). We investigated 4-, 6- and 10-cycle bursts at three power levels with the following pulse sequences: B-mode, amplitude modulation, pulse inversion and combined pulse inversion/amplitude modulation. The contrast-to-tissue (CTR) and contrast-to-artifact (CAR) ratios were calculated. At a depth of 8 mm, subharmonic pulse-inversion imaging performed the best (CTR = 26 dB, CAR = 18 dB) and at 16 mm, non-linear amplitude modulation imaging was the best contrast imaging method (CTR = 10 dB). Ultraharmonic imaging did not result in acceptable CTRs and CARs. The best candidates from the in vitro study were tested in vivo in chicken embryo and mouse models, and the results were in a good agreement with the in vitro findings.


Assuntos
Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Microbolhas , Ultrassonografia/métodos , Animais , Artefatos , Embrião de Galinha/diagnóstico por imagem , Ecocardiografia , Rim/diagnóstico por imagem , Camundongos , Imagens de Fantasmas